Compartilhamento |
![]() ![]() |
Use este identificador para citar ou linkar para este item:
http://localhost:8080/tede/handle/tede/211
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Moraes , Guto Fidalgo Daumas | - |
dc.contributor.advisor1 | Marin, Charles | - |
dc.contributor.referee1 | Rocha Filho, Hernando Valentim da | - |
dc.contributor.referee2 | Senna, Plínio Mendes | - |
dc.contributor.referee3 | Granato, Rodrigo | - |
dc.date.accessioned | 2018-07-12T16:47:22Z | - |
dc.date.issued | 2014-09-10 | - |
dc.identifier.citation | Moraes , Guto Fidalgo Daumas. Avaliação histomorfométrica de diferentes tipos de macrogeometria em implantes dentais: estudo em cães. 2014. 30 f. Dissertação( Programa de Pós-Graduação em Odontologia) - Universidade do Grande Rio, Duque de Caxias . | por |
dc.identifier.uri | http://localhost:8080/tede/handle/tede/211 | - |
dc.description.resumo | Objetivo: O objetivo desse estudo é realizar a avaliação histomorfométrica de quatro diferentes tipos de macrogeometria em implantes dentais. Materiais e Métodos: Setenta e dois implantes de 4 diferentes macrogeometrias foram implantados no rádio esquerdo de cães beagle (4 implantes por cão, 6 cães por tempo in vivo). As 4 diferentes macrogeometrias apresentavam um, dois, três ou quatro pontos de cortes em sua geometria. A eutanásia foi realizada em uma, três e seis semanas após as instalações dos implantes e foram submetidos à análise histomorfométrica através do contato osso-implante (BIC) e fração de área óssea ocupada (BAFO). A análise estatística foi realizada utilizando o teste GLM Anova. Resultados: Para o BAFO houve aumento significativo (p ≤ 0,05) dos implantes com dois pontos de corte para uma (26,69 ± 3,88), três (42,72 ± 4,19) e seis (53,92 ± 4,6) semanas. Para implantes com três pontos de cortes houve aumento significativo para uma (22,25 ± 3,88 ), três (38,86 ± 4,19) e seis(49,24 ± 4,6) semanas quando comparados aos implantes de um e quatro pontos de corte em uma (26,52 ± 4,16 / 23,69 ± 3,88), três (41,36 ± 5,05 / 38,23 ± 4,19) e seis (48,48 ± 4,6 / 45,88 ± 4,6) semanas respectivamente. Conclusões: Os resultados demonstraram que todas as macrogeometrias são biocompatíveis e os implantes com dois e três pontos de cortes apresentam melhores resultados histomorfométricos quando comparados aos implantes de um ou quatro pontos de corte. | por |
dc.description.abstract | Objective: The aim of this study is to perform the histomorphometric analysis of four different macro-geometry of dental implants using animal model. Materials and Methods: For the present study seventy-two implants of different macro-geometry were tested in the left radius of eighteen beagle dogs (6 dogs per time in vivo, 4 implants per radius). The four different designs have one, two, three or four entry points in the apex geometry. The euthanasia was performed at one, three and six weeks and the implants were processed for histomorphometric analysis by means of bone-implant contact (BIC) and bone area fraction occupied (BAFO). For statistical analysis the GLM ANOVA was used. Results: For BAFO measurements a progressive increase (p ≤ 0,05) was observed for the implants with 2 entry-points to 1 (26.69 ± 3.88), 2 (42.72 ± 4.19) and 6 (53.92 ± 4,6) weeks and progressive increase was observed for the implantes with 3 entry-points 1 (22.25 ± 3.88), 3 (38.86 ± 4.19) and 6 (49.24 ± 4.6) weeks compared to implants of a one and four entry-points 1 (26.52 ± 4.16 / 23.69 ± 3.88), 3 (41.36 ± 5.05 / 38.23 ± 4.19) and 6 (48.48 ± 4.6 / 45,88 ± 4,6) weeks respectively. Conclusion: The results of the present study showed biocompatibility of all design evaluated and the better histomophometric resuls for 2 and 3 entry-points in the 1, 3 and 6 weeks. | eng |
dc.description.provenance | Submitted by Patricia Vieira Silva ([email protected]) on 2018-07-12T16:47:22Z No. of bitstreams: 2 Guto Fidalgo Daumas Moraes 2014.pdf: 1278079 bytes, checksum: b1217e70a024c99caa8a772dfac74462 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2018-07-12T16:47:22Z (GMT). No. of bitstreams: 2 Guto Fidalgo Daumas Moraes 2014.pdf: 1278079 bytes, checksum: b1217e70a024c99caa8a772dfac74462 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2014-09-10 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade do Grande Rio | por |
dc.publisher.department | Unigranrio::Odontologia | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNIGRANRIO | por |
dc.publisher.program | Programa de Pós-Graduação em Odontologia | por |
dc.rights | Acesso Aberto | por |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Odontologia | por |
dc.subject | Implantes dentários | por |
dc.subject | Osseointegração | por |
dc.subject | Titânio | por |
dc.subject | Histologia | por |
dc.subject.cnpq | Odontologia | por |
dc.title | Avaliação histomorfométrica de diferentes tipos de macrogeometria em implantes dentais: estudo em cães | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Coleção de Pós-Graduação em Odontologia |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Guto Fidalgo Daumas Moraes 2014.pdf | Dissertação completa | 1,25 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Este item está licenciada sob uma Licença Creative Commons