Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://localhost:8080/tede/handle/tede/213
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSilva, Jonathan Ribeiro da-
dc.contributor.advisor1Granato, Rodrigo-
dc.contributor.referee1Marin, Charles-
dc.contributor.referee2Homsi, Nicolas-
dc.contributor.referee3Senna, Plínio Mendes-
dc.date.accessioned2018-07-12T17:09:04Z-
dc.date.issued2014-08-12-
dc.identifier.citationSilva, Jonathan Ribeiro da. Avaliação histomorfométrica de implantes dentários confeccionados em titânio comercialmente puro Grau IV e liga de Ti-6AI-4V Grau V. 2014. 19 f. Dissertação( Programa de Pós-Graduação em Odontologia) - Universidade do Grande Rio, Duque de Caxias .por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/213-
dc.description.resumoObjetivo: O objetivo deste estudo é realizar análise histomorfométrica da interface de dois diferentes substratos de implantes, titânio comercialmente puro grau IV, e liga de Ti-6Al-4V grau V. Materiais e Métodos: Foram instalados 18 implantes modelo Duo de cada substrato, com 10mm de comprimento e 4,6mm de diâmetro (Signo Vinces, Campo Largo, Paraná, Brasil), em 18 cães machos da raça beagle. Após eutanásia em 1, 3 e 6 semanas os implantes foram submetidos à análise histomorfométrica sendo mensurado contato osso-implante (BIC) e fração de área óssea formada (BAFO). Resultados: Houve um aumento progressivo no BIC quando analisadas a 1ª, 3ª, e 6ª semana independente do substrato. O BAFO apresentou aumento da 1ª para a 3ª semana, porem quando comparadas a 3ª e 6ª semana, a formação óssea permaneceu praticamente inalterada. Não houve diferença histomorfométrica entre o grau IV e grau V. Conclusão: O grupo experimental e controle se apresentaram biocompatíveis sem apresentar diferenças durante análise histomorfométrica, sendo necessários estudos futuros para definir indicações clínicas na implantodontia para o substrato avaliado.por
dc.description.abstractObjective: The aim of this study is perform a histomorphometric analysis between two different implants substrates available, grade IV (commercially pure titanium) and grade V (alloy Ti-6Al-4V). Materials and Methods: 18 implants of each alloy were installed in 18 male beagle dogs. The implant length was 10 mm and 4.6 mm in diameter (Signo Vinces, modelo Duo, Campo Largo, Paraná, Brazil). After euthanasia at 1, 3, and 6 weeks, the implants were subjected to histomorphometric analysis. Results: There was a progressive increase in BIC analyzed when the 1st, 3rd, and 6th week independent of the substrate. The BAFO showed an increase from the 1st to the 3rd week, however when compared the 3rd and 6th week, bone formation remained unchanged. There was no difference between the histomorphometric analysis from grade IV and grade V. Conclusion: The experimental and control groups presented no differences biocompatible for histomorphometric analysis, future studies are needed to define the clinical indications for implant dentistry rated substrate.eng
dc.description.provenanceSubmitted by Patricia Vieira Silva ([email protected]) on 2018-07-12T17:09:04Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Jonathan Ribeiro da Silva 2014.pdf: 743934 bytes, checksum: 1be6920166e8996f84a6e4d8d7bc7542 (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-07-12T17:09:04Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Jonathan Ribeiro da Silva 2014.pdf: 743934 bytes, checksum: 1be6920166e8996f84a6e4d8d7bc7542 (MD5) Previous issue date: 2014-08-12eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade do Grande Riopor
dc.publisher.departmentUnigranrio::Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIGRANRIOpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectOdontologiapor
dc.subjectImplantes dentáriospor
dc.subjectOsseointegraçãopor
dc.subjectTitâniopor
dc.subject.cnpqOdontologiapor
dc.titleAvaliação histomorfométrica de implantes dentários confeccionados em titânio comercialmente puro Grau IV e liga de Ti-6AI-4V Grau Vpor
dc.typeDissertaçãopor
Aparece nas coleções:Coleção de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Jonathan Ribeiro da Silva 2014.pdfDissertação completa726,5 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons