Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://localhost:8080/tede/handle/tede/60
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBisognin, Edecir Décio Cargnin-
dc.contributor.advisor1Vidigal Júnior, Guaracilei Maciel-
dc.contributor.advisor2Soares, Glória de Almeida-
dc.contributor.referee1Andrade Filho, Hugo de-
dc.contributor.referee2Mendes, Luiz Mota-
dc.contributor.referee3Moreira, Edson Jorge Lima-
dc.date.accessioned2016-09-26T22:52:02Z-
dc.date.issued2009-09-24-
dc.identifier.citationBisognin, Edecir Décio Cargnin. Avaliação da adaptação e capacidade de infiltração microbiana na interface implante-pilar protético em diferentes sistemas de implantes. 2009. 82 f. Dissertação( Programa de Pós-Graduação em Odontologia) - Universidade do Grande Rio, Duque de Caxias.por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/60-
dc.description.resumoA melhor adaptação entre o implante e seu componente protético parece ser importante para a homeostase perimplantar. Considerando-se que a cavidade oral é um ambiente naturalmente contaminado, é de importância que ao reabilitarem-se os implantes não se favoreça o surgimento de áreas para a deposição destes microorganismos que, poderiam causar doenças perimplantares comprometendo a osseointegração em longo prazo. Os objetivos deste estudo foram: avaliar a desadaptação e a infiltração bacteriana na interface implante-pilar protético de cinco sistemas de implante com hexágono externo, fabricados e comercializados no Brasil; e analisar a desadaptação vertical e horizontal de acordo com a classificação proposta por Kano, Binon e Curtis (2007). Foram testados oito implantes de cada uma das marcas Conexão®, Dentoflex®, Neodent®, SIN® e Titanium Fix®. Inicialmente, os conjuntos foram inoculados com 0,3μl de uma suspensão contendo Escherichia coli e colocados em meio de cultura para análise da infiltração bacteriana. A leitura das amostras foi realizada com 1, 2, 5, 7 e 14 dias para avaliação da contaminação pela turvação do meio de cultura. Após a análise microbiológica, as amostras de cada sistema foram preparadas para avaliação da adaptação através de microscopia eletrônica de varredura, com aumentos de 1000 e 3000 vezes. Os resultados revelaram que a infiltração bacteriana foi observada em 25% das amostras do sistema Dentoflex®. A desadaptação foi observada em todos os sistemas. Os valores médios de desadaptação de cada sistema foram de: Neodent® - 0,51μm ± 0,39; Dentoflex® - 1,44μm ± 0,73; Titanium Fix® - 1,88μm ± 1,28; SIN® - 2,46μm ± 3,38; Conexão® - 2,68μm ± 3,02. De acordo com a classificação de Kano, Binon e Curtis (2007), foi observada uma predominância dos tipos II e IV, de desadaptação, respectivamente, horizontal e horizontal e vertical simultaneamente. Concluiu-se que todos os grupos apresentaram desadaptação, em pelo menos um dos pontos avaliados ao longo da interface, e o aumento desta não é o único fator determinante para a ocorrência do infiltrado bacteriano, devendo-se levar em consideração também a extensão da área de acoplamento da interface, que apresentou variações entre os sistemas avaliados.por
dc.description.abstractThe best fit between the implant and the prosthetic component appears to be important for periimplant homeostasis. Considering that the oral cavity is a naturally contaminated environment, it is important that the rehabilitation with implants does not promote the emergence of areas for microorganisms deposition that might cause periimplant diseases, thus compromising the long term osseointegration. The objectives of this study were: evaluate the misfit and bacterial infiltration at the implant-abutment interface of five implant systems with external hexagon, manufactured and marketed in Brazil, and to analyze the vertical and horizontal misfit according to the classification proposed by Kano, Binon e Curtis (2007). Eight samples of each implant system: Conexão®, Dentoflex®, Neodent®, SIN® and Titanium Fix® were tested. Initially, the sets were inoculated with 0.3μl of a suspension containing Escherichia coli and placed in culture medium for analysis of bacterial infiltration. The samples analyses were performed with 1, 2, 5, 7, and 14 days for assessment of contamination through the turbidity of the culture medium. After the microbiological analysis all, samples of each system were prepared for misfits evaluation through scanning electron microscopy (SEM), with 1000x and 3000x of magnification. The results showed that the bacterial infiltration was observed in 25% of samples of the Dentoflex® system. Misfit was observed in all systems. The misfit average values of each system were: Neodent® - 0.51μm ± 0.39; Dentoflex® - 1.44μm ± 0.73; Titanium Fix® - 1.88μm ± 1.28; SIN® - 2, 46μm ± 3.38; Conexão® - 2.68μm ± 3.02. According to the classification of Kano, Binon e Curtis (2007), it was observed a predominance types II and IV of misfit, respectively, horizontal and horizontal and vertical simultaneously. It was concluded that all groups showed misfit at least in one of the points evaluated along the interface, and this increase is not the only determining factor for the occurrence of bacterial infiltration. It was also observed that the extent of the area of coupling interface should also take into account, which showed variations among the implant systems evaluated.eng
dc.description.provenanceSubmitted by Patricia Vieira Silva ([email protected]) on 2016-09-26T22:52:02Z No. of bitstreams: 1 Dissertação_Edecir Décio.pdf: 5659314 bytes, checksum: b6fe4d7fc9719a0353728f8149806bc6 (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-09-26T22:52:02Z (GMT). No. of bitstreams: 1 Dissertação_Edecir Décio.pdf: 5659314 bytes, checksum: b6fe4d7fc9719a0353728f8149806bc6 (MD5) Previous issue date: 2009-09-24eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade do Grande Riopor
dc.publisher.departmentUnigranrio::Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIGRANRIOpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectOdontologiapor
dc.subjectImplante dentáriopor
dc.subjectOsseointegraçãopor
dc.subjectInfiltração dentária-Microbiologiapor
dc.subjectImplante dentário endoósseopor
dc.subjectPerda óssea alveolarpor
dc.subjectBiomecânicapor
dc.subjectEstudos de avaliaçãopor
dc.subject.cnpqCirurgia Buco-Maxilo-Facialpor
dc.titleAvaliação da adaptação e capacidade de infiltração microbiana na interface implante-pilar protético em diferentes sistemas de implantespor
dc.typeDissertaçãopor
Aparece nas coleções:Coleção de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertação_Edecir Décio.pdfCompleto5,53 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.