Compartilhamento |
![]() ![]() |
Use este identificador para citar ou linkar para este item:
http://localhost:8080/tede/handle/tede/8
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Andrade, Altair Dantas de | - |
dc.contributor.advisor1 | Vidigal Junior, Guaracilei Maciel | - |
dc.contributor.referee1 | Soares, Glória de Almeida | - |
dc.contributor.referee2 | Moreira, Edson Jorge Lima | - |
dc.contributor.referee3 | Silveira, Eduardo Seixas | - |
dc.date.accessioned | 2016-05-09T22:24:32Z | - |
dc.date.issued | 2007-12-16 | - |
dc.identifier.citation | Andrade, Altair Dantas de. Análise comparativa da infiltração marginal apical de três cimentos endodônticos através de um processo de diafanização. 2007. 98 f. Dissertação( Programa de Pós-Graduação em Odontologia) - Universidade do Grande Rio, Duque de Caxias. | por |
dc.identifier.uri | http://localhost:8080/tede/handle/tede/8 | - |
dc.description.resumo | Existem diversos raspadores ósseos comercialmente disponíveis, apresentando diferentes características estruturais e desempenhos clínicos. Na literatura atual, não existem trabalhos que analisem as características estruturais e do projeto dos diferentes raspadores e que as relacionem a eficácia dos raspadores. O objetivo deste trabalho foi analisar os projetos, as características estruturais do aço das lâminas de corte, correlacionando com o desempenho in vitro de 9 diferentes raspadores ósseos. Os dados obtidos foram comparados utilizando a análise de variância (ANOVA) e o teste de comparações múltiplas de Student-Newman-Keuls (SNK). Além disso, a quantidade de osso raspado foi correlacionada pela análise de regressão com cada uma das outras variáveis. Os resultados demonstraram que tanto a abertura da ponta ativa, como o ângulo de corte da ponta ativa, que são características dos projetos dos raspadores ósseos, não influenciaram na quantidade de osso raspado. As características estruturais das lâminas dos raspadores ósseos (diâmetro médio de grão, dureza Vickers e composição química), influenciaram na quantidade de osso raspado. | por |
dc.description.abstract | There are many bone scrapers commercially available that present different characteristics structural and different clinic results. However, in the current literature, there are no articles that analyze the structural and project characteristics and relate them to the effectiveness of the scrapers. The aim of the present study was to analyze the design, structural characteristics of the steel of the blades from 9 different bone scrapers, as well as to relate their performance to such characteristics in vitro. The data obtained were compaired using ANOVA and the comparison multiple test Student-Newman-Keuls. Furthermore, the amount of rasped bone was related to the others variables by regression analisis. The results of the different scrapers show that both the opening and the cutting angle of the active part, which are characteristics of the bone scrapers projects, did not influence in the quantity of the scraped bone; while the structural characteristics of the bone scrapers blades (average diameter of the grain, Vickers hardness and the chemical composition) influenced in the quantity of the scraped bone. | eng |
dc.description.provenance | Submitted by Patricia Vieira Silva ([email protected]) on 2016-05-09T22:24:32Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao_Altair.pdf: 1395407 bytes, checksum: 066fe2ec8cdcadb9ab9b157c6b25d51d (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2016-05-09T22:24:32Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao_Altair.pdf: 1395407 bytes, checksum: 066fe2ec8cdcadb9ab9b157c6b25d51d (MD5) Previous issue date: 2007-12-16 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade do Grande Rio | por |
dc.publisher.department | Unigranrio::Odontologia | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNIGRANRIO | por |
dc.publisher.program | Programa de Pós-Graduação em Odontologia | por |
dc.rights | Acesso Aberto | por |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Odontologia | por |
dc.subject | Implante dentário | por |
dc.subject | Implante dentário endósseo | por |
dc.subject | Osseointegração | por |
dc.subject | Regeneração óssea | por |
dc.subject.cnpq | ODONTOLOGIA::ENDODONTIA | por |
dc.title | Raspadores ósseos : avaliação estrutural e sua relação com a eficácia in vitro | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Coleção de Pós-Graduação em Odontologia |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertacao_Altair.pdf | Dissertação | 1,36 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Este item está licenciada sob uma Licença Creative Commons