Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://localhost:8080/tede/handle/tede/99
Registro completo de metadados
Campo DCValorIdioma
dc.creatorZorzal, Marlei de Fátima Bonella-
dc.contributor.advisor1Harari, Nassim David-
dc.contributor.referee1Cançado, Renata Pittella-
dc.contributor.referee2Raymundo Júnior, Rubens-
dc.contributor.referee3Reis, Rodrigo Sant'anna Aguiar dos-
dc.date.accessioned2016-11-11T12:49:00Z-
dc.date.issued2007-04-13-
dc.identifier.citationZORZAL, Marlei de Fátima Bonella. Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco. 2007. 146 f. Dissertação (Mestrado em Odontologia) - Universidade do Grande Rio “Prof. José de Souza Herdy", Duque de Caxias.por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/99-
dc.description.resumoO planejamento do tratamento com implantes requer avaliação da região selecionada quanto à densidade, largura e altura óssea e localização das estruturas anatômicas, como o seio maxilar e canal mandibular. Todos esses aspectos evidenciam a importância de um exame radiográfico para diagnóstico que forneça boas imagens e precisão para o tratamento. Esta pesquisa teve como objetivo avaliar a precisão das tomografias convencional linear e computadorizada de feixe cônico comparadas com pontos de referência predeterminados e marcados em cinco mandíbulas e maxilas de crânios secos. Após a realização das tomografias, os crânios secos foram preparados para a execução das mensurações e estas consideradas medidas reais. As mensurações dos crânios secos e das tomografias convencionais lineares foram feitas por meio da captura das imagens obtidas e da utilização do programa AutoCAD®, enquanto as mensurações das tomografias computadorizadas de feixe cônico foram executadas com auxílio do programa DentalSlice versão 2.4.3. Na análise estatística dos resultados, o teste não-paramétrico de Wilcoxon indicou diferenças entre as medidas obtidas dos crânios secos e as das tomografias computadorizadas de feixe cônico; entre as medidas dos crânios secos e as das tomografias convencionais lineares; e entre as tomografias computadorizadas de feixe cônico e as convencionais lineares, apresentando valor de P<0,0001. Em se tratando da determinação de uma maior precisão de técnica, o teste não-paramétrico de Mann-Whitney evidenciou que os dois métodos apresentaram diferenças estatisticamente significantes, com valor de P<0,0001. As menores diferenças foram encontradas nas tomografias computadorizadas de feixe cônico.por
dc.description.abstractDental Implant treatment planning requires an accurate evaluation of bone site which includes density, width and height as well the relationship with anatomic structures such as maxillary sinus and mandibular canal. In order to have precise dental implant treatment it is important to have radiographies exams that would provide diagnosis, good quality images and accuracy to the treatment. The present study aims to evaluate the accuracy of conventional linear tomography and cone beam computerized tomography compared to predetermined and marked points of references in five dry mandibles and maxillas skulls. After all tomography were performed, the dry mandibular and maxilla bones were prepared for measurements thus considered real measurements. Dry bone and conventional linear tomography measurements were performed using the obtained image using the program AutoCAD® while the cone beam computerized tomography measurements were recorded using Dental Slice 2.4.3 software (BIOPARTS - prototipagem biomédica). Regarding, statistical analyses of the results, Wilcoxon non parametric statistic test showed differences between dry bones and cone beam computerized tomography (P<0,0001). There were differences between dry bones and conventional linear tomography (P< 0,0001). In addition, there were differences between cone beam computerized tomography and conventional linear tomography (P< 0,0001). Concerning the preciseness of technique, Mann-Whitney non parametric statistic test demonstrate that both tomography methods presented statistic significant differences, showing P<0,0001. Although, the cone beam computerized tomography presented with lower statistical significant differences.eng
dc.description.provenanceSubmitted by Janser dos Santos Nascimento ([email protected]) on 2016-11-11T12:49:00Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Marlei de Fatima Bonella Zorzal.pdf: 8993862 bytes, checksum: 2ba6b8afc99a72e85a66b65b6f9af067 (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-11-11T12:49:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Marlei de Fatima Bonella Zorzal.pdf: 8993862 bytes, checksum: 2ba6b8afc99a72e85a66b65b6f9af067 (MD5) Previous issue date: 2007-04-13eng
dc.description.sponsorshipCNPqpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade do Grande Riopor
dc.publisher.departmentUnigranrio::Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIGRANRIOpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectOdontologiapor
dc.subjectImplantes dentáriospor
dc.subjectTomografiapor
dc.subjectTomografia computadorizada de feixe cônicopor
dc.subject.cnpqODONTOLOGIApor
dc.titleAvaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio secopor
dc.typeDissertaçãopor
Aparece nas coleções:Coleção de Pós-Graduação em Ensino das Ciências

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Marlei de Fatima Bonella Zorzal.pdfCompleto8,78 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons