Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://localhost:8080/tede/handle/tede/56
Registro completo de metadados
Campo DCValorIdioma
dc.creatorAnjos, Carlos Magno dos-
dc.contributor.advisor1Harari, Nassin David-
dc.contributor.advisor2Cardoso, Eduardo Seixas-
dc.contributor.referee1Cardoso, Eduardo Seixas-
dc.contributor.referee2Oliveira, Leila Maria Chevitarese de-
dc.contributor.referee3Barboza, Eliane dos Santos Porto-
dc.date.accessioned2016-09-26T19:00:50Z-
dc.date.issued2009-09-23-
dc.identifier.citationAnjos, Carlos Magno dos. Análise in vitro da infiltração bacteriana na interface de pilares protéticos e implantes com plataforma cone morse. 2009. 48 f. Dissertação( Programa de Pós-Graduação em Odontologia) - Universidade do Grande Rio, Duque de Caxias.por
dc.identifier.urihttp://localhost:8080/tede/handle/tede/56-
dc.description.resumoA existência de microfenda entre o implante e o pilar protético possibilita o acúmulo de biofilme. A presença de bactérias nesta região tem sido descrita como fator etiológico de processos inflamatórios, tendo como consequência a desorganização dos tecidos interferindo na saúde perimplantar em longo prazo. O objetivo deste estudo foi avaliar a existência de infiltração bacteriana entre implantes com plataforma Cone Morse e pilares protéticos. A amostra foi dividida em 3 grupos com 10 corpos-de-prova cada: implantes Neodent® com pilares protéticos Neodent®, implantes Ankylos® com pilares protéticos Ankylos® e implantes Ankylos® com pilares protéticos Neodent®. As partes internas dos implantes foram inoculadas com 0,1μl de uma suspensão de Escherichia coli. Em seguida, os pilares foram fixados utilizando-se o torque recomendado pelos fabricantes e os corpos de prova imersos em caldo de cultura MacConkey. A leitura dos tubos contendo corpos-de-prova após a inoculação, que consistiu na presença ou não de turvamento devido a proliferação bacteriana, foi realizada após 1, 2, 5, 7 e 14 dias. os resultados demonstraram que nenhum dos corpos-de-prova apresentou turvamento do meio de cultura, sendo a viabilidade da bactéria comprovada através de teste controle positivo. Concluiu-se que as interfaces estudadas, tipo Cone Morse, preveniram a migração desta cepa bacteriana entre componentes de prótese e os implantes.por
dc.description.abstractThe existence of a microgap between the implant and the abutment allows the accumulation of a biofilm. The presence of bacteria in this region has been described as an etiologic factor for inflammatory processes, bringing as consequence tissue disorganization interfering in the long term peri-implant health. The objective of this study was to evaluate the existence of bacterial leakage between implants with Morse Taper platforms and abutments. The sample was divided in 3 groups with 10 specimens each: Neodent® implants with Neodent® abutments, Ankylos® implants with Ankylos® abutments and Ankylos® implants with Neodent® abutments. The inner part of the implants was inoculated with 0.1μl suspension of Escherichia coli. The abutments were screwed with the torque recommended by the manufacturers and the specimens were immersed in a broth culture MacConkey. The readings of the tubes containing the specimens after inoculation, which consisted of the presence or absence of turbidity due to bacterial growth were performed after 1, 2, 5, 7 and 14 days. Results demonstrated that none of the specimens presented turbidity of the culture medium, and the viability of the bacteria was confirmed through positive control test. It was concluded that the interfaces studied, pattern Cone Morse, prevented this strain of bacterial migration between the prosthesis and implants components.eng
dc.description.provenanceSubmitted by Patricia Vieira Silva ([email protected]) on 2016-09-26T19:00:50Z No. of bitstreams: 1 DISSERTAÇÃO - Carlos Magno 2009 .pdf: 4137418 bytes, checksum: a02be39600d7beec2723dff77aec094a (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-09-26T19:00:50Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO - Carlos Magno 2009 .pdf: 4137418 bytes, checksum: a02be39600d7beec2723dff77aec094a (MD5) Previous issue date: 2009-09-23eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade do Grande Riopor
dc.publisher.departmentUnigranrio::Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIGRANRIOpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectOdontologiapor
dc.subjectImplante dentáriopor
dc.subjectOsseointegraçãopor
dc.subjectCone Morsepor
dc.subjectInfiltração bacterianapor
dc.subject.cnpqImplantodontiapor
dc.titleAnálise in vitro da infiltração bacteriana na interface de pilares protéticos e implantes com plataforma cone morsepor
dc.typeDissertaçãopor
Aparece nas coleções:Coleção de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Carlos_Magno_2009.pdf4,04 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.